Características •ESR measurement range 0 to 20 Ohm •ESR resolution as low as 0.01 Ohm •capacitance range 1µF…22mF (22,000µF) •can also be used for low-Ohms resistance checking •built-in protection circuitry means risk of damage to the unit due to residual charge is greatly reduced •integrated controlled discharge circuitry reduces the need for the user to manually discharge capacitors before test •use in or out of circuit for ESR measurement •automatic and manual power-off
( Puede bajarse el manual en ingles clicando en botón : descargar )
Especificaciones •peak test current into S/C: ±20mA ~ ±25mA •peak test voltage across O/C: ±2.5V ~ ±3.0V •capacitance measurement range: 1µF ~ 22,000µF •capacitance accuracy: ±4%±0.2µF •ESR: ◦measurement range: 0 Ohm ~ 20 Ohm ◦resolution (ESR<2 Ohm): 0.01 Ohm ~ 0.02 Ohm ◦resolution (ESR>2 Ohm): 0.1 Ohm ~ 0.2Ohm ◦accuracy (ESR<2 Ohm): ±1.5% ±0.02 Ohm ◦accuracy (ESR>2 Ohm): ±1.5% ±0.2O